AODE Machinery Co.,Ltd is one of the toppest Air Cooled Packaged Industrial Chiller (R410A 460V-60HZ) in China.During these years of exporting , AODE Machinery Co.,Ltd now has rich experience in the worldwide markets
Air Cooled Packaged Industrial Chiller (R410A 460V-60HZ)
Features
◆ The unit include inverse phase, high and low pressure, thermal overload, low level, antifreeze protection, etc
◆ The unit use high strength welded frame
◆ Well-known brand compressor
◆ The water tank and water pipe made of stainless steel SUS304
◆ The refrigeration valve from Danfoss, Emerson, Sporlan and other well-known brands
◆ Electrical components supplied from SIEMENS, Schneider, EATON and other famous brands
◆ The standard unit has remote switch interface and fault transmission interface, RS485 communication function is optional
◆ Adopts microcomputer automatic control or PLC control
◆ Refrigerants can be selected ,such as R407C, R404A, R134A, R410A etc
◆ Other evaporator type can be selected,such as stainless steel plate heat exchanger, shell and tube type, coil type, and Acid and alkali resistant type
◆ The frame color can also be customized according to customer requirements
Item | Unit | Model | ||||||||||||
AC-06AS | AC-08AS | AC-10AS | AC-12AS | AC-15AS | AC-20AS | AC-25AD | AC-30AD | AC-40AD | AC-50AF | AC-60AF | AC-80AF | |||
Size | RT | 5 | 6 | 7.5 | 10 | 12 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | |
Cooling Capacity(60Hz) | Btu/h | 62600 | 72000 | 92450 | 125200 | 144000 | 184900 | 250400 | 288000 | 369900 | 500900 | 576000 | 739800 | |
kcal/h | 15750 | 18100 | 23300 | 31500 | 36200 | 46600 | 63100 | 72500 | 93200 | 126200 | 145100 | 186400 | ||
Total Power Inout | HP | 9 | 10 | 14 | 18 | 20 | 27 | 36 | 40 | 54 | 73 | 81 | 105 | |
Maximum Running Current | amps | 12 | 14 | 18 | 24 | 27 | 35 | 48 | 54 | 71 | 97 | 109 | 138 | |
Power Supply Cable Diameter | mm2 | 3×4+2×4 | 3×6+2×4 | 3×6+2×4 | 3×6+2×4 | 3×6+2×4 | 3×10+2×4 | 3×10+2×4 | 3×25+2×10 | 3×25+2×10 | 3×70+2×35 | 3×70+2×35 | 3×95+2×50 | |
Refrigerant | R410A | |||||||||||||
Control Type | Digital temperature display microcomputer controller | |||||||||||||
Power Supply Type | 3N,460V,60Hz | |||||||||||||
Safety Protection Device | Overload、Inverse Phase、High/Low Pressure、Water Flow、Water Level、Antifreeze Protection,etc | |||||||||||||
Compressor | Type | Hermetic Scroll Type | ||||||||||||
Motor Power | HP | 7.5×1 | 9×1 | 11×1 | 15×1 | 17×1 | 22×1 | 15×2 | 17×2 | 22×2 | 15×4 | 17×4 | 22×4 | |
Condenser | Type | Finned Tubes | ||||||||||||
Air Flow | cfm | 3500 | 4400 | 5850 | 7000 | 8800 | 11700 | 14100 | 17600 | 23500 | 28200 | 35200 | 47000 | |
Fan Motor Power | HP | 0.3×2 | 0.6×2 | 0.7×2 | 0.9×2 | 0.9×2 | 0.9×3 | 0.9×4 | 0.9×4 | 0.9×6 | 0.9×8 | 0.9×8 | 0.9×12 | |
Evaporator | Type | Dry Shell And Tube Type | ||||||||||||
Water Pressure Drop | psi | ≤12 | ||||||||||||
Process connections(NPT) | inches | 1.0 | 1.5 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.5 | |
Tank | Volume | gal | 30 | 50 | 50 | 50 | 50 | 50 | 100 | 100 | 100 | 150 | 150 | 150 |
Pump | Flow | gpm | 13.9 | 16.1 | 20.5 | 27.8 | 32.2 | 41.0 | 55.5 | 63.9 | 81.9 | 111.0 | 127.8 | 164.3 |
Pressure | psi | 40.6 | 40.6 | 40.6 | 40.6 | 40.6 | 47.9 | 45.0 | 42.1 | 46.4 | 47.9 | 43.5 | 43.5 | |
Motor Power | HP | 1.0 | 1.0 | 1.4 | 1.4 | 1.4 | 2.0 | 2.4 | 2.4 | 4.0 | 5.3 | 5.3 | 5.3 | |
Outline Size | ||||||||||||||
Length | inches | 48 | 58 | 58 | 91 | 91 | 134 | 91 | 91 | 134 | 177 | 177 | 260 | |
Width | inches | 26 | 28 | 28 | 43 | 43 | 43 | 87 | 87 | 87 | 87 | 87 | 87 | |
Height | inches | 55 | 64 | 64 | 71 | 71 | 71 | 79 | 79 | 79 | 79 | 79 | 79 | |
Net weight | lbs | 800 | 1000 | 1150 | 1210 | 1430 | 1760 | 2090 | 2640 | 2970 | 3300 | 3970 | 4850 | |
Run weight | lbs | 1200 | 1400 | 1620 | 1740 | 1960 | 2290 | 3150 | 3700 | 4030 | 4890 | 5560 | 6440 | |
Sound Pressure @ 1 meter | dBA | 68 | 70 | 70 | 72 | 72 | 73 | 74 | 74 | 75 | 75 | 75 | 76 | |
Refrigerant Charge | lbs | 10 | 15 | 18 | 20 | 30 | 35 | 50 | 60 | 70 | 100 | 130 | 150 | |
Remarks: | ||||||||||||||
1.Cooling tons based on 10℃(50℉) leaving coolant and 35℃(95℉) ambient air;Water side fouling coefficient of 0.086m2•℃/kW. | ||||||||||||||
2.Chilled water work allowed temperature range: 5℃~35℃(41℉~95℉). Chilled water in and out temperature difference: 3℃~8℃(37.4℉~46.4℉); Allowed ambient temperature range: -10℃~40℃(14℉~104℉). | ||||||||||||||
3.Please pay attention to verify whether pump pressure to meet customer's requirement,Net available pressure at outlet of chiller is pump discharge pressure less internal coolant circuit pressure loss;R407C、R134A、R404A or R410A is also available,Corresponding technical parameters are changed, must be separately provided. | ||||||||||||||
4.Allowed the voltage range ±10%,Allowed phase voltage difference ±2%,Allowed the frequency range ±0.2Hz. | ||||||||||||||
5.Default framework color RAL 7000, metal sheet color RAL 9005,if need to change, please inform in advance. | ||||||||||||||
6.We reserve the rights to change the parameters without notice. |